ACXChapter



Assertion Log 117 entries
Status Time Condition / Message
PASS 12:10:11 acx-chapter-leveler-none-calibrate-program: rendered sample rate is 44100 Hz
PASS 12:10:14 acx-chapter-leveler-none-apply-rilla_female_very_soft: rendered sample rate is 44100 Hz
PASS 12:10:14 acx-chapter-leveler-none-apply-anne_female_peak_stressed: rendered sample rate is 44100 Hz
PASS 12:10:14 acx-chapter-leveler-none-apply-uncle_tom_male_neutral: rendered sample rate is 44100 Hz
PASS 12:10:14 acx-chapter-leveler-none-apply-lord_jim_male_soft: rendered sample rate is 44100 Hz
PASS 12:10:14 acx-chapter-leveler-none-apply-jeeves_male_hot: rendered sample rate is 44100 Hz
PASS 12:10:14 acx-chapter-leveler-none-apply-secret_garden_female_soft: rendered sample rate is 44100 Hz
PASS 12:10:14 acx-chapter-leveler-none-apply-program: rendered sample rate is 44100 Hz
PASS 12:10:14 Limiter disabled: two-pass chapter-sequence file RMS: measured=-20.499888 dBFS, target=-20.500000 dBFS, delta=0.000112 dBFS, tol<=0.250000 dBFS
PASS 12:10:14 Limiter disabled / Female very soft - Karen Savage: ACX file RMS band (measured=-19.78 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:14 Limiter disabled / Female peak-stressed - Annie Coleman Rothenberg: ACX file RMS band (measured=-20.16 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:14 Limiter disabled / Male neutral - John Greenman: ACX file RMS band (measured=-20.24 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:14 Limiter disabled / Male soft - Stewart Wills: ACX file RMS band (measured=-20.72 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:14 Limiter disabled / Male hot - Mark Nelson: ACX file RMS band (measured=-20.74 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:14 Limiter disabled / Female soft - Kara Shallenberg: ACX file RMS band (measured=-20.82 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:14 Limiter disabled / Chapter sequence: ACX file RMS band (measured=-20.50 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:14 Limiter disabled: fixed two-pass compensation (calibration_file_rms=-22.64 dBFS, applied_delta=+2.14 dB)
PASS 12:10:16 acx-chapter-leveler-peak-calibrate-program: rendered sample rate is 44100 Hz
PASS 12:10:19 acx-chapter-leveler-peak-apply-rilla_female_very_soft: rendered sample rate is 44100 Hz
PASS 12:10:19 acx-chapter-leveler-peak-apply-anne_female_peak_stressed: rendered sample rate is 44100 Hz
PASS 12:10:19 acx-chapter-leveler-peak-apply-uncle_tom_male_neutral: rendered sample rate is 44100 Hz
PASS 12:10:19 acx-chapter-leveler-peak-apply-lord_jim_male_soft: rendered sample rate is 44100 Hz
PASS 12:10:19 acx-chapter-leveler-peak-apply-jeeves_male_hot: rendered sample rate is 44100 Hz
PASS 12:10:19 acx-chapter-leveler-peak-apply-secret_garden_female_soft: rendered sample rate is 44100 Hz
PASS 12:10:19 acx-chapter-leveler-peak-apply-program: rendered sample rate is 44100 Hz
PASS 12:10:19 Built-in Peak: two-pass chapter-sequence file RMS: measured=-20.622766 dBFS, target=-20.500000 dBFS, delta=0.122766 dBFS, tol<=0.250000 dBFS
PASS 12:10:19 Built-in Peak / Female very soft - Karen Savage: ACX file RMS band (measured=-19.91 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:19 Built-in Peak / Female very soft - Karen Savage: ACX sample peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:19 Built-in Peak / Female peak-stressed - Annie Coleman Rothenberg: ACX file RMS band (measured=-20.19 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:19 Built-in Peak / Female peak-stressed - Annie Coleman Rothenberg: ACX sample peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:19 Built-in Peak / Male neutral - John Greenman: ACX file RMS band (measured=-20.64 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:19 Built-in Peak / Male neutral - John Greenman: ACX sample peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:19 Built-in Peak / Male soft - Stewart Wills: ACX file RMS band (measured=-20.90 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:19 Built-in Peak / Male soft - Stewart Wills: ACX sample peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:19 Built-in Peak / Male hot - Mark Nelson: ACX file RMS band (measured=-20.73 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:19 Built-in Peak / Male hot - Mark Nelson: ACX sample peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:19 Built-in Peak / Female soft - Kara Shallenberg: ACX file RMS band (measured=-20.83 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:19 Built-in Peak / Female soft - Kara Shallenberg: ACX sample peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:19 Built-in Peak / Chapter sequence: ACX file RMS band (measured=-20.62 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:19 Built-in Peak / Chapter sequence: ACX sample peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:19 Built-in Peak: fixed two-pass compensation (calibration_file_rms=-22.65 dBFS, applied_delta=+2.15 dB)
PASS 12:10:21 acx-chapter-leveler-true_peak-calibrate-program: rendered sample rate is 44100 Hz
PASS 12:10:25 acx-chapter-leveler-true_peak-apply-rilla_female_very_soft: rendered sample rate is 44100 Hz
PASS 12:10:25 acx-chapter-leveler-true_peak-apply-anne_female_peak_stressed: rendered sample rate is 44100 Hz
PASS 12:10:25 acx-chapter-leveler-true_peak-apply-uncle_tom_male_neutral: rendered sample rate is 44100 Hz
PASS 12:10:25 acx-chapter-leveler-true_peak-apply-lord_jim_male_soft: rendered sample rate is 44100 Hz
PASS 12:10:25 acx-chapter-leveler-true_peak-apply-jeeves_male_hot: rendered sample rate is 44100 Hz
PASS 12:10:25 acx-chapter-leveler-true_peak-apply-secret_garden_female_soft: rendered sample rate is 44100 Hz
PASS 12:10:25 acx-chapter-leveler-true_peak-apply-program: rendered sample rate is 44100 Hz
PASS 12:10:25 Built-in True Peak: two-pass chapter-sequence file RMS: measured=-20.631881 dBFS, target=-20.500000 dBFS, delta=0.131881 dBFS, tol<=0.250000 dBFS
PASS 12:10:25 Built-in True Peak / Female very soft - Karen Savage: ACX file RMS band (measured=-19.91 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:25 Built-in True Peak / Female very soft - Karen Savage: ACX true peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:25 Built-in True Peak / Female peak-stressed - Annie Coleman Rothenberg: ACX file RMS band (measured=-20.20 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:25 Built-in True Peak / Female peak-stressed - Annie Coleman Rothenberg: ACX true peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:25 Built-in True Peak / Male neutral - John Greenman: ACX file RMS band (measured=-20.68 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:25 Built-in True Peak / Male neutral - John Greenman: ACX true peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:25 Built-in True Peak / Male soft - Stewart Wills: ACX file RMS band (measured=-20.90 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:25 Built-in True Peak / Male soft - Stewart Wills: ACX true peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:25 Built-in True Peak / Male hot - Mark Nelson: ACX file RMS band (measured=-20.73 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:25 Built-in True Peak / Male hot - Mark Nelson: ACX true peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:25 Built-in True Peak / Female soft - Kara Shallenberg: ACX file RMS band (measured=-20.83 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:25 Built-in True Peak / Female soft - Kara Shallenberg: ACX true peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:25 Built-in True Peak / Chapter sequence: ACX file RMS band (measured=-20.63 dBFS, allowed=-23.00..-18.00 dBFS)
PASS 12:10:25 Built-in True Peak / Chapter sequence: ACX true peak ceiling (measured=-3.01 dBFS, limit=-3.00 dBFS)
PASS 12:10:25 Built-in True Peak: fixed two-pass compensation (calibration_file_rms=-22.66 dBFS, applied_delta=+2.16 dB)
PASS 12:10:28 RMS validation view / Female very soft - Karen Savage: Meter produced finite source measurements
PASS 12:10:28 RMS validation view / Female very soft - Karen Savage: Meter produced finite output measurements
PASS 12:10:28 RMS validation view / Female peak-stressed - Annie Coleman Rothenberg: Meter produced finite source measurements
PASS 12:10:28 RMS validation view / Female peak-stressed - Annie Coleman Rothenberg: Meter produced finite output measurements
PASS 12:10:28 RMS validation view / Male neutral - John Greenman: Meter produced finite source measurements
PASS 12:10:28 RMS validation view / Male neutral - John Greenman: Meter produced finite output measurements
PASS 12:10:28 RMS validation view / Male soft - Stewart Wills: Meter produced finite source measurements
PASS 12:10:28 RMS validation view / Male soft - Stewart Wills: Meter produced finite output measurements
PASS 12:10:28 RMS validation view / Male hot - Mark Nelson: Meter produced finite source measurements
PASS 12:10:28 RMS validation view / Male hot - Mark Nelson: Meter produced finite output measurements
PASS 12:10:28 RMS validation view / Female soft - Kara Shallenberg: Meter produced finite source measurements
PASS 12:10:28 RMS validation view / Female soft - Kara Shallenberg: Meter produced finite output measurements
PASS 12:10:28 RMS validation view / Chapter sequence: Meter produced finite source measurements
PASS 12:10:28 RMS validation view / Chapter sequence: Meter produced finite output measurements
PASS 12:10:28 Sample peak check / Female very soft - Karen Savage: Meter produced finite source measurements
PASS 12:10:28 Sample peak check / Female very soft - Karen Savage: Meter produced finite output measurements
PASS 12:10:28 Sample peak check / Female peak-stressed - Annie Coleman Rothenberg: Meter produced finite source measurements
PASS 12:10:28 Sample peak check / Female peak-stressed - Annie Coleman Rothenberg: Meter produced finite output measurements
PASS 12:10:28 Sample peak check / Male neutral - John Greenman: Meter produced finite source measurements
PASS 12:10:28 Sample peak check / Male neutral - John Greenman: Meter produced finite output measurements
PASS 12:10:28 Sample peak check / Male soft - Stewart Wills: Meter produced finite source measurements
PASS 12:10:28 Sample peak check / Male soft - Stewart Wills: Meter produced finite output measurements
PASS 12:10:28 Sample peak check / Male hot - Mark Nelson: Meter produced finite source measurements
PASS 12:10:28 Sample peak check / Male hot - Mark Nelson: Meter produced finite output measurements
PASS 12:10:28 Sample peak check / Female soft - Kara Shallenberg: Meter produced finite source measurements
PASS 12:10:28 Sample peak check / Female soft - Kara Shallenberg: Meter produced finite output measurements
PASS 12:10:28 Sample peak check / Chapter sequence: Meter produced finite source measurements
PASS 12:10:28 Sample peak check / Chapter sequence: Meter produced finite output measurements
PASS 12:10:28 True peak check / Female very soft - Karen Savage: Meter produced finite source measurements
PASS 12:10:28 True peak check / Female very soft - Karen Savage: Meter produced finite output measurements
PASS 12:10:28 True peak check / Female peak-stressed - Annie Coleman Rothenberg: Meter produced finite source measurements
PASS 12:10:28 True peak check / Female peak-stressed - Annie Coleman Rothenberg: Meter produced finite output measurements
PASS 12:10:28 True peak check / Male neutral - John Greenman: Meter produced finite source measurements
PASS 12:10:28 True peak check / Male neutral - John Greenman: Meter produced finite output measurements
PASS 12:10:28 True peak check / Male soft - Stewart Wills: Meter produced finite source measurements
PASS 12:10:28 True peak check / Male soft - Stewart Wills: Meter produced finite output measurements
PASS 12:10:28 True peak check / Male hot - Mark Nelson: Meter produced finite source measurements
PASS 12:10:28 True peak check / Male hot - Mark Nelson: Meter produced finite output measurements
PASS 12:10:28 True peak check / Female soft - Kara Shallenberg: Meter produced finite source measurements
PASS 12:10:28 True peak check / Female soft - Kara Shallenberg: Meter produced finite output measurements
PASS 12:10:28 True peak check / Chapter sequence: Meter produced finite source measurements
PASS 12:10:28 True peak check / Chapter sequence: Meter produced finite output measurements
PASS 12:10:28 Female very soft - Karen Savage: offline ACX gate reference (file_rms=-19.91 dBFS, class=inside, sample_peak=-3.01 dBFS, class=inside, meter_true_peak=-3.01 dBTP, class=inside)
PASS 12:10:28 Female peak-stressed - Annie Coleman Rothenberg: offline ACX gate reference (file_rms=-20.20 dBFS, class=inside, sample_peak=-3.01 dBFS, class=inside, meter_true_peak=-3.01 dBTP, class=inside)
PASS 12:10:28 Male neutral - John Greenman: offline ACX gate reference (file_rms=-20.68 dBFS, class=inside, sample_peak=-3.01 dBFS, class=inside, meter_true_peak=-3.01 dBTP, class=inside)
PASS 12:10:28 Male soft - Stewart Wills: offline ACX gate reference (file_rms=-20.90 dBFS, class=inside, sample_peak=-3.01 dBFS, class=inside, meter_true_peak=-3.01 dBTP, class=inside)
PASS 12:10:28 Male hot - Mark Nelson: offline ACX gate reference (file_rms=-20.73 dBFS, class=inside, sample_peak=-3.01 dBFS, class=inside, meter_true_peak=-3.01 dBTP, class=inside)
PASS 12:10:28 Female soft - Kara Shallenberg: offline ACX gate reference (file_rms=-20.83 dBFS, class=inside, sample_peak=-3.01 dBFS, class=inside, meter_true_peak=-3.01 dBTP, class=inside)
PASS 12:10:28 Chapter sequence: offline ACX gate reference (file_rms=-20.63 dBFS, class=inside, sample_peak=-3.01 dBFS, class=inside, meter_true_peak=-3.01 dBTP, class=inside)
PASS 12:10:28 Validation - QC Chapter: Leveler delivery candidates are inside the ACX RMS window
PASS 12:10:28 Validation - QC Chapter: Leveler delivery candidates are inside the ACX sample-peak ceiling
PASS 12:10:28 Validation - QC Chapter: Leveler delivery candidates are inside the ACX true-peak ceiling